期刊论文详细信息
BMC Sports Science, Medicine and Rehabilitation
The bilateral limb deficit (BLD) phenomenon during leg press: a preliminary investigation into central and peripheral factors
Emily Whitcomb1  Oscar Ortiz1  Jacqueline Toner1  Usha Kuruganti1 
[1] Andrew and Marjorie McCain Human Performance Laboratory, Faculty of Kinesiology, University of New Brunswick, E3B 5A3, Fredericton, NB, Canada;
关键词: Bilateral limb deficit phenomenon;    Surface electromyography;    Electroencephalography;    Leg press;    Movement related cortical potential;   
DOI  :  10.1186/s13102-021-00321-0
来源: Springer
PDF
【 摘 要 】

BackgroundThe bilateral limb deficit (BLD) phenomenon suggests that lower forces are produced with bilateral limb contractions compared to the summed force produced when the same muscles are contracted unilaterally. While interhemispheric inhibition has been suggested as a cause of BLD, the origin of the deficit is yet to be determined. The aim of this study was to investigate central and peripheral factors responsible for the BLD during leg press using surface electromyography (EMG) and electroencephalography (EEG).MethodsFourteen adults (age = 23.7 ± 4.7 years old) completed bilateral (BL), unilateral left (UL) and unilateral right (UR) isometric leg press exercises. Bilateral limb ratio (BLR) was calculated similar to previous studies and surface EMG from three muscles of the quadriceps femoris (vastus lateralis, vastus medialis and rectus femoris) was used to measure the level of muscle activation. Movement related cortical potentials (MRCPs) over the left and right motor cortex areas (C3 and C4, respectively) were used to assess brain activity asymmetries reflecting central factors.ResultsNo significant difference was noted in the mean BLR (BLR = 94.8%), but a subset of ten participants did demonstrate a BLD (BLR = 81.4%, p < 0.01). Mean differences in relative activation were found among the three quadricep muscles (p < 0.001) with the right VM having significantly higher amplitude for the unilateral right (0.347 ± 0.318 mV) and bilateral right (0.436 ± 0.470 mV) conditions, respectively) than either the VL or RF (p < 0.05). The VL had significantly lower amplitudes in all conditions (0.127 ± 0.138 mV; 0.111 ± 0.104 mV; 0.120 ± 0.105 mV; 0.162 ± 0.147 mV for unilateral left, bilateral left, unilateral right, and bilateral right, respectively). However no overall significant differences were noted between bilateral and unilateral conditions. No significant differences in MRCPs were observed between brain activity of the C3 and C4 electrodes in any of the conditions.ConclusionWhile the sample size was low, this exploratory study noted the presence of BLD however the results did not provide evidence of significant limitations in either the EMG or EEG data.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202109175928841ZK.pdf 1255KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:5次