期刊论文详细信息
Insights into Imaging
Hemosiderin deposition evaluation in hemophilic ankle joints: association between US finding and gradient-recalled echo MR imaging sequence
Joedo Prihartono1  Novie Amelia Chozie2  Marcel Prasetyo3  Stefanus Imanuel Setiawan3  Ariel Elisa Mongan3 
[1] Departement of Community Medicine, Faculty of Medicine, Universitas Indonesia, Jakarta, Indonesia;Department of Pediatric, Faculty of Medicine, Universitas Indonesia – Dr. Cipto Mangunkusumo National Central General Hospital, Jakarta, Indonesia;Department of Radiology, Faculty of Medicine, Universitas Indonesia – Dr. Cipto Mangunkusumo National Central General Hospital, Jl. Diponegoro No.71, 10430, Jakarta Pusat, DKI Jakarta, Indonesia;
关键词: Hemosiderin deposition;    Hemophilic arthropathy;    US;    GRE MR imaging;   
DOI  :  10.1186/s13244-021-01050-1
来源: Springer
PDF
【 摘 要 】

BackgroundRepeated bleeding in hemophilic arthropathy (HA) may result in severe degenerative changes and joint destruction. The gradient-recalled echo (GRE) sequence MR is proved to be the best method to detect hemosiderin deposition. However, MR is not widely available in developing countries, including Indonesia. Some studies have proposed ultrasonography (US) as an alternative tool in evaluating hemophilic joint. However, there is still some disagreement on the ability of US to detect hemosiderin deposition.ObjectiveTo evaluate the association between US and GRE-sequence MR imaging in detecting hemosiderin deposition in hemophilic ankle joint.Material and methodsA total of 102 sites from 17 ankle joints of 11 boys with severe hemophilia A underwent US examination using a high-frequency linear array transducer. GRE-sequence MR examination was performed in sagittal view consistent with the sites scanned by US. Both examinations were performed on the same day, but MR interpretation was performed blindly at different times. The association between US and GRE-sequences in detecting hemosiderin deposition was analyzed using McNemar’s test.ResultsStatistical analysis showed a significant association (p value < 0.001) between US and GRE MR in detecting hemosiderin deposition, but the association is weak (R = 0.26). Sensitivity and specificity of US for detecting hemosiderin deposition were 46.84% (95%CI: 35.51–58.40) and 95.65% (95%CI: 78.05–99.89), respectively, with positive predictive value 97.37% (95%CI: 84.29–99.61), negative predictive value 34.38% (95%CI: 29.50–39.60) and accuracy 57.84% (95%CI: 47.66–67.56).ConclusionThere was a weak association between US and GRE-sequences in detecting hemosiderin deposition of hemophilic ankle joint. ​​

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202108126797310ZK.pdf 1470KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:2次