期刊论文详细信息
International Journal of Implant Dentistry
Impact of the blooming artefact on dental implant dimensions in 13 cone-beam computed tomography devices
Ruben Pauwels1  Matheus L. Oliveira2  Sohaib Shujaat3  Karla de Faria Vasconcelos3  Reinhilde Jacobs4  Andre Ferreira Leite5  Victor Aquino Wanderley6 
[1] Aarhus Institute of Advanced Studies, Aarhus University, Aarhus, Denmark;Department of Mechanical Engineering, Catholic University of Leuven, Leuven, Belgium;Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil;OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium;OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium;Department of Dental Medicine, Karolinska Institutet, Stockholm, Sweden;OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium;Department of Dentistry, Faculty of Health Sciences University of Brasília, Brasília, Brazil;OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium;Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil;
关键词: Artefacts;    Cone-beam computed tomography;    Dental implants;   
DOI  :  10.1186/s40729-021-00347-6
来源: Springer
PDF
【 摘 要 】

BackgroundThe purpose of this study was to objectively assess dimensional alteration (blooming artefact) on dental implant using 13 cone-beam computed tomography (CBCT) devices adjusted to device-specific scanning protocols and to assess whether subjective adjustment of brightness and contrast (B&C) could alter its visualization.MethodsAn anthropomorphic phantom containing a dental implant was scanned in 13 CBCT devices adjusted to three scanning protocols: medium-FOV standard resolution, small-FOV standard resolution, and small-FOV high resolution. The diameter of the implant was measured at five levels, averaged, and compared with those from a reference standard industrial CT image. B&C adjustments were performed and measurements were repeated. The intraclass correlation coefficient assessed the reliability of the measurements and general linear mixed models were applied for multiples comparisons at a 95% confidence interval.ResultsImplant diameter obtained from small-FOV high-resolution protocols in most CBCT devices was not significantly different when compared to that from the reference (p > 0.05). For standard protocols, significant dimensional alteration of the implant ranging from 23 to 34% (0.67 to 1.02 mm) was observed in 9 CBCT devices for small-FOV scanning (p < 0.05), and in 8 CBCT devices for medium-FOV scanning, implant dimensional alteration ranged significantly from 21 to 35% (0.62 to 1.04 mm). After B&C adjustments, dimensional alteration was reduced for several of the CBCT devices tested (p < 0.05).ConclusionsThe visualization of the implant dimensional alteration differed between CBCT devices and scanning protocols with an increase in diameter ranging from 0.27 to 1.04 mm. For most CBCT devices, B&C adjustments allowed to reduce visualization of implant blooming.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202108124224440ZK.pdf 3410KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:10次