期刊论文详细信息
Egyptian Journal of Forensic Sciences
Assessment of QIAGEN™ Investigator® 24plex GO! kit workflow for autosomal STR profiling of forensic reference samples
article
Hakim, Hashom Mohd1  Khan, Hussein Omar1  Ismail, Siti Afifah1  Lazim, Nurul Hazirah Mat1  Lalung, Japareng2  Kofi, Abban Edward4  Chambers, Geoffrey Keith5  Edinur, Hisham Atan4 
[1]DNA Databank Division (D13), Criminal Investigation Department, Royal Malaysian Police
[2]School of Industrial Technology, Universiti Sains Malaysia
[3]Department of Chemistry Malaysia
[4]Forensic Science Programme, School of Health Sciences, Health Campus, Universiti Sains Malaysia
[5]School of Biological Sciences, Victoria University of Wellington
[6]Environmental Futures Research Institute, Griffith University
[7]Institute of Tropical Biodiversity and Sustainable Development, Universiti Malaysia Terengganu
关键词: Buccal swabs cell;    Investigator® 24plex GO!;    GlobalFiler™ Express;    Reference samples;    DNA database;    Autosomal STR;    DNA typing;   
DOI  :  10.1186/s41935-020-00203-5
学科分类:心脏病和心血管学
来源: Springer
PDF
【 摘 要 】
DNA profiling has proven to be a valuable technique for identification of individuals in crime. Currently, the technique targets several short tandem repeat (STR) regions in human genome. However, increasing number of samples submitted for STR analysis may lead to delays due to the limited number of experienced analysts who might be available at any given moment and the time taken to complete lengthy DNA profiling procedures. This study was conducted to test the specificity, repeatability, reproducibility and robustness of Investigator® 24plex GO! kit for genotyping of reference samples submitted to the Royal Malaysian Police Forensic DNA Laboratory for DNA database. In this study, Investigator® 24plex GO! kit was used to directly amplify STR loci from buccal swab cell of reference samples that had previously been STR typed using GlobalFiler™ Express kit. Capillary electrophoresis was carried out on a 3500xL Genetic Analyser using POP-4® Polymer. Amplified products were assigned to particular STR alleles using the GeneMapper ID-X version 1.4 software. Our study shows that STR profiles generated using Investigator® 24plex GO! gave concordance results with those previously obtained using the GlobalFiler™ Express kit. In addition, quality sensors included in the kit are of particular importance for determining the effectiveness of the PCR reaction and help to indicate the nature and quantity of DNA template for PCR amplification. The Investigator® 24plex GO! kit is reliable for STR typing of reference samples.
【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202108090004123ZK.pdf 1003KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:0次