期刊论文详细信息
Acta Geophysica
Comparison of emissivity retrieval methods from ASTER data using Fourier-Transform Infrared Spectroscopy
article
Rolim, Silvia Beatriz Alves1  Veettil, Bijeesh Kozhikkodan2  Käfer, Pâmela Suélen1  Grondona, Atilio Efrain Bica1  Iglesias, María Luján1  Diaz, Lucas Ribeiro1  Hackmann, Cristiano Lima1 
[1] Geologic Remote Sensing Laboratory (LabSRGeo), Universidade Federal do Rio Grande do Sul (UFRGS);Department for Management of Science and Technology Development, Ton Duc Thang University;Faculty of Environment and Labour Safety, Ton Duc Thang University
关键词: Land surface emissivity;    ASTER data;    Thermal infrared;    Quartz;   
DOI  :  10.1007/s11600-020-00498-x
学科分类:地球科学(综合)
来源: Polska Akademia Nauk * Instytut Geofizyki
PDF
【 摘 要 】

Land surface emissivity retrieval is important for the remote identification of natural materials and can be used to identify the presence of silicate minerals. However, its estimation from passive sensors involves an undetermined function related to radiance data, which is influenced by the atmosphere. We tested three methods for temperature emissivity retrieval in a dune field composed of 99.53% quartz (SiO2) using Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) imagery. The tested methods were the reference channel method (RCM), emissivity normalization method (ENM), and temperature emissivity separation (TES) method. An average quartz reference spectrum for the dune samples was calculated from an emissivity database based on temperature and used to evaluate the emissivity products of four ASTER images. In general, the three tested methods had a good approximation when analysed the emissivity reference curve, especially for longer wavelengths that ranged between 2 and 4% of emissivity. The RCM and ENM produced very similar results with the coefficients of determination (R2) as 0.9960 (RMSE 0.0184) and 0.9959 (RMSE 0.0185), respectively. RCM method presented superior results (R2: 0.9960, RMSE: 0.0184), compared to the TES method (R2: 0.9947, RMSE: 0.0197). The TES method showed good results only for shorter wavelengths and, hence, to identify specific targets using ASTER data, such as silicate minerals, it is better to use the RCM method. The emissivity value selected at the saturation point of the spectral library based on temperature is fundamental in acquiring more reliable data.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO202108090001784ZK.pdf 3112KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:2次