Journal of Orthopaedic Surgery and Research
The EOS 3D imaging system reliably measures posterior tibial slope
Frank M. Klenke1  Andreas Hecker1  Emanuel F. Liechti1  Rainer J. Egli2  Till D. Lerch2 
[1] Department of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland;University Institute for Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland;
关键词: Tibial slope;    Planning HTO;    EOS;    Sagittal lower leg alignment;    Long leg radiographs;   
DOI  :  10.1186/s13018-021-02529-9
来源: Springer
PDF
【 摘 要 】

BackgroundOne of the values determined during the assessment of knee issues is the posterior tibial slope (PTS). A new option for measuring the PTS is the EOS 3D imaging system, which provides anteroposterior (AP) and lateral long leg radiographs (LLRs) using less radiation than a conventional LLR. We investigated the reliability of the EOS 3D imaging system with respect to PTS measurements.MethodsWe retrospectively searched our radiological database for patients who underwent an EOS scan and a computed tomography (CT) scan of their lower extremities between January and December 2019. Fifty-six knees were included in the study. Medial and lateral PTSs were determined using both modalities. A radiologist and an orthopaedic surgeon each performed all measurements twice and the intraclass correlation (ICC) was calculated to assess inter- and intrarater reliability. The Student t test and Pearson correlation were used to compare the results of both imaging modalities.ResultsThe mean medial PTS was 8.5° (95% confidence interval [CI], 8.1–8.9°) for the EOS system and 7.7° (95% CI, 7.3–8.1°) for CT, and the lateral PTS was 7.4° (95% CI, 6.9–7.9°) for the EOS system, and 7.0° (95% CI, 6.5–7.4°) for CT. Interrater reliability (ICC) with respect to medial and lateral PTSs measured on the EOS (0.880, 0.765) and CT (0.884, 0.887) images was excellent. The intrarater reliability of reader 1 (ICC range, 0.889–0.986) and reader 2 (ICC range, 0.868–0.980) with respect to the same measurements was excellent.ConclusionThe PTS measurements from the EOS 3D imaging system are as reliable and reproducible as those from CT, the current gold standard method. We recommend using this system if possible, because it acquires more information (sagittal plane) in a scan than a conventional LLR, while exposing the patient to less radiation.Level of evidenceLevel III, Retrospective cohort study

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202107223456422ZK.pdf 664KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:1次