Introduction
The performance and limitations of an atlas-based auto-segmentation software package (ABAS; Elekta Inc.) was evaluated using male pelvic anatomy as the area of interest.
| Journal of Medical Radiation Sciences | |
| Evaluation of atlas‐based auto‐segmentation software in prostate cancer patients | |
| Stuart Greenham DipAppSc(TherRad), MIR, BAppScComp4  Jenna Dean BMedRadSc(RT)2  Cheuk Kuen Kenneth Fu BSC Rad (RT), MBT1  Joanne Goman BMedRadSc(RT)3  Jeremy Mulligan BMedRadSc(RT)2  Deanna Tune BAppSc(MRT)4  David Sampson BAppSc(MRT)1  Justin Westhuyzen MSc, PhD4  | |
| [1] North Coast Cancer Institute, Lismore Health Campus, Lismore, New South Wales, Australia;North Coast Cancer Institute, Port Macquarie Health Campus, Port Macquarie, New South Wales, Australia;Department of Radiation Oncology, Calvary Mater Newcastle, Newcastle, New South Wales, Australia;Department of Radiation Oncology, North Coast Cancer Institute, Coffs Harbour Health Campus, Coffs Harbour, New South Wales, Australia | |
| 关键词: Computer assisted; computer‐generated 3D imaging; diagnostic imaging; pelvis; prostate; radiotherapy planning; | |
| DOI : 10.1002/jmrs.64 | |
| 来源: Wiley | |
PDF
|
|
The performance and limitations of an atlas-based auto-segmentation software package (ABAS; Elekta Inc.) was evaluated using male pelvic anatomy as the area of interest. Contours from 10 prostate patients were selected to create atlases in ABAS. The contoured regions of interest were created manually to align with published guidelines and included the prostate, bladder, rectum, femoral heads and external patient contour. Twenty-four clinically treated prostate patients were auto-contoured using a randomised selection of two, four, six, eight or ten atlases. The concordance between the manually drawn and computer-generated contours were evaluated statistically using Pearson's product–moment correlation coefficient (r) and clinically in a validated qualitative evaluation. In the latter evaluation, six radiation therapists classified the degree of agreement for each structure using seven clinically appropriate categories. The ABAS software generated clinically acceptable contours for the bladder, rectum, femoral heads and external patient contour. For these structures, ABAS-generated volumes were highly correlated with ‘as treated’ volumes, manually drawn; for four atlases, for example, bladder r = 0.988 (P < 0.001), rectum r = 0.739 (P < 0.001) and left femoral head r = 0.560 (P < 0.001). Poorest results were seen for the prostate (r = 0.401, P < 0.05) (four atlases); however this was attributed to the comparison prostate volume being contoured on magnetic resonance imaging (MRI) rather than computed tomography (CT) data. For all structures, increasing the number of atlases did not consistently improve accuracy. ABAS-generated contours are clinically useful for a range of structures in the male pelvis. Clinically appropriate volumes were created, but editing of some contours was inevitably required. The ideal number of atlases to improve generated automatic contours is yet to be determined.Abstract
Introduction
Methods
Results
Conclusions
CC BY-NC
© 2014 The Authors. Journal of Medical Radiation Sciences published by Wiley Publishing Asia Pty Ltd on behalf of Australian Institute of Radiography and New Zealand Institute of Medical Radiation Technology.
Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
| Files | Size | Format | View |
|---|---|---|---|
| RO202107150014356ZK.pdf | 767KB |