Micro & nano letters | |
Modelling, microfabrication and performance evaluation of non-spiral planar microcoils for biomedical wireless power transfer systems | |
article | |
Krishnapriya Sudhakaran1  Rama Komaragiri2  Suja Krishnan Jagada1  | |
[1] Department of Electronics and Communication;Department of Electronics and Communication, Bennett University | |
关键词: inductive power transmission; magnetic shielding; microfabrication; coils; Bessel functions; CMOS integrated circuits; analytical model; nonspiral microcoil; electrical model; nonspiral planar microcoil; wireless power transfer link; biomedical wireless power transfer applications; microfabrication; biomedical wireless power transfer systems; mathematical modelling; existing very-large-scale integration manufacturing process; single mask level; single metal level; complementary metal oxide semiconductor sensing circuitry; | |
DOI : 10.1049/mnl.2019.0158 | |
学科分类:计算机科学(综合) | |
来源: Wiley | |
【 摘 要 】
Microfabrication, electrical characterisation, and mathematical modelling of a non-spiral planar microcoil useful for wireless power transfer applications in biomedical devices are presented in this work. The fabrication method using the existing very-large-scale integration manufacturing process requires a single mask level, and a single metal level without any via enables direct integration with a complementary metal oxide semiconductor sensing circuitry. An analytical model of magnetic field distribution in a non-spiral microcoil is developed for the first time in this work, which satisfies the form of a Bessel function of the first kind. An electrical model of the non-spiral planar microcoil is also developed and compared with experimental results. Experimental results are in good agreement with the theoretical model. Based on the experimental results, using optimised coil geometry, a wireless power transfer link suitable for biomedical wireless power transfer applications is studied. The maximum possible value of coupling factor of the wireless link is found to be 60% for a small separation between the coil and the magnet whereas the minimum value of coupling factor is found to be below 10% for large separations. It is found that introducing Neodymium magnetic shield layer at the receiving coil enhances the coupling factor significantly.
【 授权许可】
CC BY|CC BY-ND|CC BY-NC|CC BY-NC-ND
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202107100002659ZK.pdf | 583KB | download |