期刊论文详细信息
Healthcare Technology Letters
Development and face validation of ultrasound-guided renal biopsy virtual trainer
article
Andinet Enquobahrie1  Sam Horvath1  Sreekanth Arikatla1  Avi Rosenberg2  Kevin Cleary3  Karun Sharma3 
[1] Kitware Inc;School of Medicine, Johns Hopkins University;Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Health System
关键词: biomedical ultrasonics;    public domain software;    paediatrics;    computer based training;    diseases;    patient treatment;    medical computing;    surgery;    biomedical education;    kidney;    needles;    kidney failure;    renal pathologies;    competent biopsy technique;    high yield biopsy samples;    virtual simulator;    procedural skill competence;    US-guided renal biopsy;    low-cost hardware components;    open source software libraries;    face validation;    US images;    needle visualisation;    US-guided needle biopsy;    clinical experts;    clinical validation study;    ultrasound-guided renal biopsy virtual trainer;    chronic kidney disease;    adult-paediatric nephrologists;    interventional-diagnostic radiologists;    hand-eye coordination;    Web-based application;    automated skill assessment;    tracking modules;    time 3.0 year to 23.0 year;   
DOI  :  10.1049/htl.2019.0081
学科分类:肠胃与肝脏病学
来源: Wiley
PDF
【 摘 要 】

The overall prevalence of chronic kidney disease in the general population is ∼14% with more than 661,000 Americans having a kidney failure. Ultrasound (US)-guided renal biopsy is a critically important tool in the evaluation and management of renal pathologies. This Letter presents KBVTrainer, a virtual simulator that the authors developed to train clinicians to improve procedural skill competence in US-guided renal biopsy. The simulator was built using low-cost hardware components and open source software libraries. They conducted a face validation study with five experts who were either adult/pediatric nephrologists or interventional/diagnostic radiologists. The trainer was rated very highly (>4.4) for the usefulness of the real US images (highest at 4.8), potential usefulness of the trainer in training for needle visualization, tracking, steadiness and hand-eye coordination, and overall promise of the trainer to be useful for training US-guided needle biopsies. The lowest score of 2.4 was received for the look and feel of the US probe and needle compared to clinical practice. The force feedback received a moderate score of 3.0. The clinical experts provided abundant verbal and written subjective feedback and were highly enthusiastic about using the trainer as a valuable tool for future trainees.

【 授权许可】

CC BY|CC BY-ND|CC BY-NC|CC BY-NC-ND   

【 预 览 】
附件列表
Files Size Format View
RO202107100000884ZK.pdf 268KB PDF download
  文献评价指标  
  下载次数:4次 浏览次数:0次