期刊论文详细信息
BMC Musculoskeletal Disorders
Immersion in Raloxifene does not significantly improve bone toughness or screw pull-out strength in multiple in vitro models
Danielle M. Cristino1  Michael W. Hast1  Jaimo Ahn2  Kendall M. Masada3  Matthew Counihan3  Michael R. Eby3 
[1] Biedermann Lab for Orthopaedic Research, University of Pennsylvania, 3450 Hamilton Walk, 373A Stemmler Hall, 19104, Philadelphia, PA, USA;Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI, USA;Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA;
关键词: Raloxifene;    Fracture repair;    Proximal humerus;    Cadaveric;    Biomechanics;   
DOI  :  10.1186/s12891-021-04342-1
来源: Springer
PDF
【 摘 要 】

BackgroundFailure of surgical fixation in orthopaedic fractures occurs at a significantly higher rate in osteoporotic patients due to weakened osteoporotic bone. A therapy to acutely improve the mechanical properties of bone during fracture repair would have profound clinical impact. A previous study has demonstrated an increase in mechanical properties of acellular cortical canine bone after immersion in raloxifene. The goal of this study was to determine if similar treatment yields the same results in cancellous fetal bovine bone and whether this translates into a difference in screw pull-out strength in human cadaveric tissue.MethodsCancellous bone from fetal bovine distal femora underwent quasi-static four-point bending tests after being immersed in either raloxifene (20 μM) or phosphate-buffered saline as a control for 7 days (n = 10). Separately, 5 matched pairs of human osteoporotic cadaveric humeral heads underwent the same procedure. Five 3.5 mm unicortical cancellous screws were then inserted at standard surgical fixation locations to a depth of 30 mm and quasi-static screw pull-out tests were performed.ResultsIn the four-point bending tests, there were no significant differences between the raloxifene and control groups for any of the mechanical properties - including stiffness (p = 0.333) and toughness (p = 0.546). In the screw pull-out tests, the raloxifene soaked samples and control samples had pullout strengths of 122 ± 74.3 N and 89.5 ± 63.8 N, respectively.ConclusionsResults from this study indicate that cancellous fetal bovine samples did not demonstrate an increase in toughness with raloxifene treatment, which is in contrast to previously published data that studied canine cortical bone. In vivo experiments are likely required to determine whether raloxifene will improve implant fixation.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202107075342767ZK.pdf 1498KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:4次