期刊论文详细信息
BMC Musculoskeletal Disorders
Different diagnostic performance of plasma fibrinogen and D-dimer in periprosthetic joint infection: a propensity score matched study
Yiou Wang1  Shibai Zhu1  Jin Lin1  Xisheng Weng1  Jin Jin1  Xi Chen1  Wenwei Qian1 
[1] Department of Orthopedic Surgery, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China;
关键词: Periprosthetic joint infection;    Fibrinogen;    D-dimer;   
DOI  :  10.1186/s12891-021-04282-w
来源: Springer
PDF
【 摘 要 】

BackgroundFibrinogen (Fbg) and D-dimer have been used as biomarkers for the diagnosis of periprosthetic joint infection (PJI). However, previous research has reported conflicting results on the diagnostic value of D-dimer in comparison to Fbg, C-reactive protein (CRP), and erythrocyte sedimentation rate (ESR).AimThis study aimed to: (1) determine the optimal threshold of plasma Fbg and D-dimer in the diagnosis of PJI and compare their diagnostic value to that of CRP and ESR; and (2) investigate whether Fbg and D-dimer perform differently than CRP and ESR as diagnostic indicators for different types of PJI.MethodsA total of 115 revision cases after total hip arthroplasty (THA) and total knee arthroplasty (TKA) were identified. Based on demographic characteristics, 25 culture-positive cases were matched to 50 culture-negative cases using propensity score matching. Sensitivity, specificity, receiver operating characteristics (ROC), negative predictive value (NPV), and positive predictive value (PPV) were calculated and compared.ResultsThe optimal thresholds were 2.72 mg/L for D-dimer, 3.655 g/L for Fbg, 12.64 mg/L for CRP, and 27 mm/h for ESR. Levels of plasma Fbg, D-dimer, CRP, and ESR were significantly higher in the culture-positive group than the culture-negative group. Fbg, D-dimer, CRP, and ESR showed sensitivity of 0.92, 0.56, 0.92, and 0.88, respectively, and showed specificity of 0.84, 0.96, 0.94, and 0.80, respectively. The ROC curve showed that CRP has the highest area under the curve (AUC) (0.94), followed by Fbg (0.90), ESR (0.87), and D-dimer (0.81).ConclusionsPlasma Fbg exhibited a similar diagnostic performance compared to CRP and ESR in predicting culture-positive results in PJI. Plasma D-dimer showed high specificity but low sensitivity. In our study, Fbg and D-dimer did not show better diagnostic performance with different pathogens and different types of PJI. Further studies are required to investigate the difference between serum D-dimer and plasma D-dimer in the arthroplasty population.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202107068517481ZK.pdf 588KB PDF download
  文献评价指标  
  下载次数:22次 浏览次数:10次