International Journal of Geo-Engineering | |
Feasibility evaluation of the 3D-DIC non contact measurement system using small-scaled model test of earth retaining wall | |
Moonkyung Chung1  Seunghwan Seo1  Younghun Ko1  Tailie Jin2  | |
[1] Korea Institute of Civil Engineering and Building Technology, 283 Goyang-daero, Ilsanseo-gu, 10223, Goyang-si, Gyeonggi-do, Republic of Korea;Omagom Limited Company, 66, Munji-Ro, 299Beong-Gil, Yuseong-Gu, Dajeon, Republic of Korea; | |
关键词: Digital image correlation; Earth retaining wall; Noncontact displacement measurement; Stereo camera; | |
DOI : 10.1186/s40703-021-00141-8 | |
来源: Springer | |
【 摘 要 】
In this study, a small scale experiment of an earth retaining wall was conducted to develop a real-time and full-field noncontact measurement system for earth retaining walls in urban areas. The collapse behavior of the structure was reproduced using a model of an earth retaining wall, and the deformation and displacement of the entire surface of the small scale structure were measured using a 3D image-based digital-image correlation method employing a stereo camera system. The measured displacement was compared with the actual displacement by using high-precision hexapod equipment in the experiment, and the results confirmed a high level of precision.