期刊论文详细信息
International Journal of Geo-Engineering
Feasibility evaluation of the 3D-DIC non contact measurement system using small-scaled model test of earth retaining wall
Moonkyung Chung1  Seunghwan Seo1  Younghun Ko1  Tailie Jin2 
[1] Korea Institute of Civil Engineering and Building Technology, 283 Goyang-daero, Ilsanseo-gu, 10223, Goyang-si, Gyeonggi-do, Republic of Korea;Omagom Limited Company, 66, Munji-Ro, 299Beong-Gil, Yuseong-Gu, Dajeon, Republic of Korea;
关键词: Digital image correlation;    Earth retaining wall;    Noncontact displacement measurement;    Stereo camera;   
DOI  :  10.1186/s40703-021-00141-8
来源: Springer
PDF
【 摘 要 】

In this study, a small scale experiment of an earth retaining wall was conducted to develop a real-time and full-field noncontact measurement system for earth retaining walls in urban areas. The collapse behavior of the structure was reproduced using a model of an earth retaining wall, and the deformation and displacement of the entire surface of the small scale structure were measured using a 3D image-based digital-image correlation method employing a stereo camera system. The measured displacement was compared with the actual displacement by using high-precision hexapod equipment in the experiment, and the results confirmed a high level of precision.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202107060545965ZK.pdf 3061KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:12次