Preliminary feasibility torque mechanical evaluation for 3D printed orthodontic springs with different parameters: in vitro study
Dragan Ströbele1  Jassin Arnold1  Ahmed Othman1  Steven Hartman1  von See1 
[1] Digital Technologies in Dentistry and CAD/CAM Department, Danube Private University, Steiner Landstraße 124, 3500, Krems an der Donau, Austria;
关键词: CAD/CAM;    3D printing;    Digital orthodontics;    Torque;    Springs;   
DOI  :  10.1186/s12903-021-01473-8
来源: Springer
PDF
【 摘 要 】

BackgroundThe purpose of the presented investigation is to evaluate the resulting torque on loaded 3D printed springs using different coil thickness and length.MethodsSpecimens were designed and printed using the 3D printer MAX (Asiga, Sydney, Australia) with 3D printable, experimental, flexible material (Code:BM2008, GC, Tokyo, Japan). The specimens were divided into three groups according to spring coil design. Control group (n = 18), length group (n = 19) and thickness group (n = 22). Groups were tested using a Sauter Machine for torque calculation (DB, Grindelwald, Switzerland) in conjunction with a universal testing machine (Zwick Z010, Ulm, Germany) for clock-wise and anti-clockwise testing. Statistical analysis was performed using the Steel–Dwass test to compare median values of the three groups in both testing directions (p < 0.001).ResultsThe highest torque value was determined in the thickness group for both clockwise and anti-clockwise testing directions, achieving 44.00 N/mm and 39.62 N/mm respectively. The length group ranged from 21.65 to 11.04 N/mm in clockwise direction and from 18.04 to 11.38 N/mm in counter-clockwise testing. The control group ranged from 22.72 to 17.18 N/mm in the clock-wise direction while in the anti-clock wise testing it ranged from 21.34 to 16.02 N/mm.ConclusionsThe amount of torque produced from the computer aided designing/computer aided manufacturing (CAD/CAM) springs is being affected by diameter more than the length design parameter in comparison to the control group. The values of the thickness group are significantly higher than those of the length group (P < 0.001).

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202107027341597ZK.pdf 976KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:1次