期刊论文详细信息
Animal Biotelemetry
Validating Star-Oddi heart rate and acceleration data storage tags for use in Atlantic salmon (Salmo salar)
A. Kurt Gamperl1  Zoe Amanda Zrini1 
[1] Department of Ocean Sciences, Memorial University, A1C 5S7, St. John’s, NL, Canada;
关键词: Data storage tags;    Atlantic salmon;    Heart rate;    Surgical recovery;    Acceleration;    Swimming speed;    Calibration;   
DOI  :  10.1186/s40317-021-00235-1
来源: Springer
PDF
【 摘 要 】

BackgroundData storage tags (DSTs) record and store information about animals and their environment, and can provide important data relevant to fish culture, ecology and conservation. A DST has recently been developed that records heart rate (fH), electrocardiograms (ECGs), tri-axial acceleration and temperature. However, at the time of this study, no research using these tags had been performed on fish or determined the quality of the data collected. Thus, our research asked: do these DSTs provide reliable and meaningful data? To examine this question, Atlantic salmon (1.4 ± 0.7 kg) were implanted with DSTs, then swam at increasing speeds in a swim tunnel after 1 week of recovery. Further, in two separate experiments, salmon (2.4 ± 0.1 kg) were implanted with DSTs and held in a large tank with conspecifics for 1 week at 11 °C or 6 weeks at 8–12 °C.ResultsExternal acceleration (EA) and variation in EA (VAR) increased exponentially with swimming speed and tail beat frequency. The quality index (QI) assigned to ECG recordings (where QI0 means very good quality, and QI1, QI2 and QI3 are of reduced quality) did not change significantly with increasing swimming speed (QI0 ~ 60–80%). However, we found that the accuracy of the tag algorithm in estimating fH from ECGs was reduced when QI>0. Diurnal patterns of fH and EA were evident from the time the salmon were placed in the tank. Heart rate appeared to stabilize by ~ 4 days post-surgery in the first experiment, but extended holding showed that fH declined for 2–3 weeks. During extended holding, the tag had difficulty recording low fH values < 30 bpm, and for this reason, in addition to the fact that the algorithm can miscalculate fH, it is highly recommended that ECGs be saved when possible for quality control and so that fH values with QI>0 can be manually calculated.ConclusionsWith these DSTs, parameters of acceleration can be used to monitor the activity of free-swimming salmon. Further, changes in fH and heart rate variability (HRV) due to diurnal rhythms, and in response to temperature, activity and stressors, can be recorded.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202107026353799ZK.pdf 1871KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:6次