Journal of Osseointegration | |
Histology of a dental implant with a platform switched implant-abutment connection | |
article | |
Marco Degidi1  Vittoria Perrotti2  Adriano Piattelli2  Jamil A. Shibli3  Giovanna Iezzi2  | |
[1] Private Practice;Dental School, University of Chieti-Pescara;Department of Periodontology, Dental Research Division, and Head of Oral Implantology Clinic, Guarulhos University | |
关键词: Crestal bone remodelling; Histology; Immediate loading; Microgap; Platform switching; Retrieved dental implants.; | |
DOI : 10.23805/jo.2011.03.03.02 | |
学科分类:社会科学、人文和艺术(综合) | |
来源: Ariesdue | |
【 摘 要 】
Background Peri-implant crestal bone must be stable for aesthetic reasons. Aim of this study was a histologic analysis of an implant with a platform switched implant-abutment connection. A 32-year-old male patient participated in this study. The patient needed a bilateral mandibular restoration. Four implants were used, and were immediately restored and loaded the same day of insertion. After a 6 weeks healing period, one implant with platform-switched abutment was retrieved with trephine. Before retrieval the implant was osseointegrated and not mobile. On one side of the implant, a 1 mm resorption of the crestal bone was present. On the contrary, on the other side no bone resorption had occurred and about 1 mm of bone was present over the implant shoulder. The bone-implant contact percentage was 65.1 ± 6.3 %. Platform- switching could help in maintaining the height of the peri-implant crestal bone.
【 授权许可】
CC BY-NC-ND
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202105240001358ZK.pdf | 116KB | download |