Effect of PTH and corticotomy on implant movement under mechanical force
Jin-Woo Kim1  Heon-Young Kim1  Won-Ho Kim2  Min-Ji Kim2  Jiyeon Kim3 
[1]Department of Oral and Maxillofacial Surgery, School of Medicine, Ewha Womans University, Anyangcheon-ro 1071, Yangcheon-gu, 158-710, Seoul, South Korea
[2]Department of Orthodontics, School of Medicine, Ewha Womans University, Anyangcheon-ro 1071, Yangcheon-gu, 158-710, Seoul, South Korea
[3]School of Medicine, Ewha Womans University, Seoul, South Korea
关键词: Implant;    Bone remodeling;    Parathyroid hormone;    Corticotomy;    Orthodontic force;   
DOI  :  10.1186/s12903-020-01310-4
来源: Springer
PDF
【 摘 要 】
BackgroundOsseointegrated implants are considered as clinically non-movable. Parathyroid hormone (PTH) is known to play a significant role in the regulation of bone remodeling and in intermittent, low doses, result in osteoanabolic effects. This study aimed to investigate the effects of PTH and corticotomy, both under traction force, on osseointegrated implants.MethodsFour implants—two in each hemimandible—were placed in each of the three study mongrels. Each mongrels were designated as control, normal dose PTH (PTH-1), and high dose PTH (PTH-2) groups, with each groups further subdivided into non-surgery implant and surgery implant. After osseointegration, mechanical force with NiTi closed coil springs (500 g) was applied around each implants. Corticotomy was performed around one of four implants in each mongrels. Parathyroid hormone was administered locally on a weekly basis for 20 weeks. Clinical movement of the implants were evaluated with the superimposed 3D- scanned data, bone- microarchitectural and histologic examinations.ResultsSuperimposition analysis showed continuous movement of the non-surgery implant of PTH-1 group. Movement was further justified with lowest bone implant contact (adjusted BIC; 44.77%) in histomorphometric analysis. Upregulation of bone remodeling around the implant was observed in the normal dose PTH group. In the surgery implants, the remarkably higher adjusted BIC compared to the non-surgery implants indicated increased bone formation around the implant surface.ConclusionThe results indicate that the catabolic and anabolic balance of osseointegrated implants in terms of bone remodeling can be shifted via various interventions including pharmacological, surgical and mechanical force.Clinical relevanceUpregulated bone remodeling by PTH and corticotomy under continuous mechanical force showed the possible implications for the movement of osseointegrated dental implant.
【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202104281119807ZK.pdf 3749KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:1次