Non-invasive measurement of choroid plexus apparent blood flow with arterial spin labeling | |
Weiying Dai1  Li Zhao2  Daniel Z. Press3  Manuel Taso4  David C. Alsop4  | |
[1] Computer Science, State University of New York At Binghamton, Binghamton, NY, USA;Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China;Neurology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA;Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA; | |
关键词: Choroid plexus; Cerebrospinal fluid; Perfusion; Magnetic resonance imaging; Arterial spin labeling; | |
DOI : 10.1186/s12987-020-00218-z | |
来源: Springer | |
【 摘 要 】
BackgroundThe choroid plexus is a major contributor to the generation of cerebrospinal fluid (CSF) and the maintenance of its electrolyte and metabolite balance. Here, we sought to characterize the blood flow dynamics of the choroid plexus using arterial spin labeling (ASL) MRI to establish ASL as a non-invasive tool for choroid plexus function and disease studies.MethodsSeven healthy volunteers were imaged on a 3T MR scanner. ASL images were acquired with 12 labeling durations and post labeling delays. Regions of the choroid plexus were manually segmented on high-resolution T1 weighted images. Choroid plexus perfusion was characterized with a dynamic ASL perfusion model. Cerebral gray matter perfusion was also quantified for comparison.ResultsKinetics of the ASL signal were clearly different in the choroid plexus than in gray matter. The choroid plexus has a significantly longer T1 than the gray matter (2.33 ± 0.30 s vs. 1.85 ± 0.10 s, p < 0.02). The arterial transit time was 1.24 ± 0.20 s at the choroid plexus. The apparent blood flow to the choroid plexus was measured to be 39.5 ± 10.1 ml/100 g/min and 0.80 ± 0.31 ml/min integrated over the posterior lateral ventricles in both hemispheres. Correction with the choroid plexus weight yielded a blood flow of 80 ml/100 g/min.ConclusionsOur findings suggest that ASL can provide a clinically feasible option to quantify the dynamic characteristics of choroid plexus blood flow. It also provides useful reference values of the choroid plexus perfusion. The long T1 of the choroid plexus may suggest the transport of water from arterial blood to the CSF, potentially providing a method to quantify CSF generation.
【 授权许可】
CC BY
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202104245427347ZK.pdf | 2091KB | download |