BMC Musculoskeletal Disorders | |
Concurrent validity and reliability of measuring range of motion during the cervical flexion rotation test with a novel digital goniometer | |
Max Obrocki1  Maike Grassold1  Christine Reimer1  Christian Neulinger2  Philipp Przyhoda2  Axel Schäfer2  Thomas Schoettker-Königer2  Petra Hasselhoff-Styhler2  Kerstin Luedtke3  Toby Hall4  | |
[1] Faculty of Social Sciences, University of Applied Sciences Bremen, Neustadtswall 30, 28199, Bremen, Germany;Faculty of Social Work and Health, University of Applied Science and Art (HAWK), Goschentor 1, 31134, Hildesheim, Germany;Laboratory of Pain Research, Institute of Physiotherapy and Health Sciences, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland;Institute of Health Sciences, Academic Physiotherapy, University of Luebeck, Lübeck, Germany;School of Physiotherapy and Exercise Science, Curtin University, Perth, WA, Australia; | |
关键词: Reliability; Validity; Intra-rater; Inter-rater; Flexion-rotation-test; Neck pain; Headache; Cervical; Zebris; Goniometer; | |
DOI : 10.1186/s12891-020-03525-6 | |
来源: Springer | |
【 摘 要 】
BackgroundHeadache is a common and costly health problem. Although the pathogenesis of headache is heterogeneous, reported contributing factors are dysfunctions of the upper cervical spine. The flexion rotation test (FRT) is a commonly used diagnostic test to detect upper cervical movement impairment. A digital goniometer may support precise measurement of movement impairment in the upper cervical spine. However, its reliability and validity is not assessed, yet. The aim of this study was to investigate the reliability and validity of the digital goniometer compared to an ultrasound-based movement analysis system.MethodsTwo separate cross-sectional studies were conducted using the digital goniometer EasyAngle (Meloq AB, Stockholm, Sweden) for a) investigating the concurrent validity of upper cervical range of motion (ROM) during the FRT and b) determining the inter- and intra-rater reliability in the target population of patients with head and neck pain. Sixty-two participants, 39 with and 23 without head and neck pain, were recruited for the concurrent validity study. For the reliability study, a total of 50 participants were recruited. Intraclass correlation coefficients (ICC) and Bland Altmann plots were used to assess validity and ICC values, Bland Altmann plots as well as Kappa coefficients were used for estimating intra-rater and inter-rater reliability.ResultsConcurrent validity was strong with an ICC (2,1) of 0.97 for ROM to either side (95%CI = 0.95–0.98). Bland Altman Plots revealed a mean difference between measurement systems of 0.5° for the left and 0.11° for the right side.The inter-rater ICC (2,1) was 0.66 (95%CI 0.47–0.79, p < 0.001, SEM 6.6°), indicating good reliability. The limits of agreement were between 10.25° and − 11.89°, the mean difference between both raters was − 0.82°. Intra-rater reliability for the measurement of ROM during the FRT was between 0.96 (ICC 3,1) for rater 1 and 0.94 (ICC 3,1) for rater 2.ConclusionsThe digital goniometer demonstrated strong concurrent validity and good to strong reliability and can be used in clinical practice to accurately determine movement impairment in the upper cervical spine.Trial registrationGerman Registry of Clinical Trials DRKS00013051.
【 授权许可】
CC BY
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202104241891627ZK.pdf | 3374KB | download |