Accuracy of doppler ultrasonography in the evaluation of hemodialysis arteriovenous fistula maturity
João Humberto Da Fonseca Junior1  Guilherme Benjamin Brandão Pitta1  Fausto Miranda Júnior1 
关键词: Arteriovenous Fistula;    Hemodialysis;    Ultrasonography;    Doppler;    Color;    Fístula arteriovenosa;    Hemodiálise;    Ultrassonografia Doppler em Cores;   
DOI  :  10.1590/0100-69912015003002
来源: SciELO
PDF
【 摘 要 】

OBJECTIVE:to determine the accuracy of Doppler ultrasonography (USD) for hemodialysis arteriovenous fistula (AVF) maturity. METHODS:we included patients with no prior AVF. Each patient underwent two USD examinations. After initiation of hemodialysis, we followed the patients during the first month of the access use and verified its adequacy to hemodialysis sessions. At statistical analysis we measured specificity, sensitivity, accuracy, ROC curve (Receiver operator characteristic) curve, TG-ROC (Two graph - receiver operator characteristic) and logistic regression. RESULTS:we included 76 patients, of which 51 completed the study. They formed two groups, those who have had good adequacy for hemodialysis (45) and those who had not (6). The average flow volume (FV) and the average draining vein diameter (DVD) of each group were, respectively: 940mL/min (95% CI: 829-1052) and 325mL/min (95% CI: 140-510); and 0.48cm (95% CI: 0.45-0.52) and 0.33cm (95% CI: 0.27-0.40). The area under the ROC curve of FV and DVD were 0.926 and 0.766, respectively. CONCLUSION:the accuracy of the measured volume flow measured at the draining vein to evaluate maturation of hemodialysis arteriovenous fistula was 85%.

【 授权许可】

CC BY   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202103040069930ZK.pdf 379KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:3次