Química Nova | |
Validação de método analítico livre de acetonitrila para análise de microcistinas por cromatografia líquida de alta eficiência | |
Sérvio Túlio Alves Cassini1  Paulo Wagner Pereira Antunes1  Regina Keller1  | |
[1] ,Universidade Federal do Espírito Santo Departamento de Engenharia Ambiental Vitória ES ,Brasil | |
关键词: microcystin; acetonitrile; methanol; | |
DOI : 10.1590/S0100-40422013000800019 | |
来源: SciELO | |
【 摘 要 】
Blooms of cyanobacteria represent a public health risk due to their cyanotoxins such as microcystins. Liquid chromatography techniques to separate and quantify microcystins invariably use acetonitrile as the organic component of the mobile phase. The price and availability of acetonitrile together with its elevated toxicity encourage the validation of acetonitrile-free methods of microcystin analysis. In this work, methanol was employed as the organic solvent of the mobile phase and the validation method was performed with different environmental water samples. The method showed limits of detection between 0.17 and 0.25 µg/L and of quantification between 0.55 and 0.82 µg/L for the microcystin variants: -RR, -YR, -LR, -LA.
【 授权许可】
CC BY-NC
All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202103040064354ZK.pdf | 568KB | download |