期刊论文详细信息
Química Nova
Análise de agrotóxicos em água usando extração líquido-líquido com partição em baixa temperatura por cromatografia líquida de alta eficiência
Flaviano Oliveira Silvério1  Joyce Grazielle Siqueira Silva1  Maria Clara Santana Aguiar1  Ane Patrícia Cacique1  Gevany Paulino De Pinho1 
[1] ,Universidade Federal de Minas Gerais Instituto de Ciências Agrárias Montes Claros MG ,Brasil
关键词: LLE-LTP;    pesticides;    HPLC-UV;   
DOI  :  10.1590/S0100-40422012001000027
来源: SciELO
PDF
【 摘 要 】

This study optimized and validated the liquid-liquid extraction technique with partition at low temperature (LLE-PLT) for identification and quantification of four pesticides (chlorpyrifos, λ-cyhalothrin, permethrin, bifenthrin) in water samples. Analyses were performed by HPLC-UV. The technique was efficient for pesticide recovery with extraction exceeding 86%. Chromatographic response was linear for the four compounds in the 10-45 µg L-1 range, with correlation coefficients greater than 0.99. Limits of detection and quantitation were less than 3.5 µg L-1 and equal to 10 µg L-1, respectively. The proposed method was applied to 29 water samples from the Jaíba Project in northern Minas Gerais.

【 授权许可】

CC BY-NC   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202103040064115ZK.pdf 1575KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:2次