期刊论文详细信息
Química Nova
Otimização e validação da técnica de extração líquido-líquido com partição em baixa temperatura (ELL-PBT) para piretróides em água e análise por CG
Heulla Pereira Vieira1  Antônio Augusto Neves1  Maria Eliana Lopes Ribeiro De Queiroz1 
[1] ,Universidade Federal de Viçosa Departamento de Química Viçosa MG ,Brasil
关键词: pyrethroid;    validation;    gas chromatography;   
DOI  :  10.1590/S0100-40422007000300006
来源: SciELO
PDF
【 摘 要 】

The liquid-liquid extraction with the low temperature partition technique was developed for the analysis of four pyrethroids in water by CG. Using a factorial design the extraction technique was optimised evaluating the effect of the variables ionic strength, contact time and proportion between sample and solvent volumes. The validation parameters sensitivity, precision, accuracy and detection and quantification limits were evaluated. The LOD and LOQ of the method varied from 1.1 to 3.2 µg L-1 and 2.7 to 9.5 µg L-1, respectively.

【 授权许可】

CC BY-NC   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202103040062040ZK.pdf 197KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:4次