| Brazilian Journal of Microbiology | |
| Polyclonal anti-intimin antibody: immunological characterization and its use in EPEC and EHEC diagnosis | |
| Paula Célia Mariko Koga2  Caroline Anunciação Menezes2  Flávia Afonso Lima2  Júlia Mitico Nara2  Caroline Arantes Magalhães2  Aurora Marques Cianciarullo1  Jorge Mario Da Costa Ferreira-júnior1  Luiz Rachid Trabulsi2  Meire Roberta Bresciani Mendes-ledesma2  Roxane Maria Fontes Piazza2  | |
| [1] ,Laboratório Especial de MicrobiologiaSão Paulo SP ,Brasil | |
| 关键词: intimin; phenotypical analysis; polyclonal antibody; EPEC; EHEC; intimina; análise fenotípica; anticorpo policlonal; EPEC; EHEC; | |
| DOI : 10.1590/S1517-83822003000500002 | |
| 来源: SciELO | |
PDF
|
|
【 摘 要 】
Intimins are outer membrane proteins expressed by enteric bacterial pathogens capable of inducing intestinal attachment-and-effacement lesion (A/E). Through immunoblotting, immunofluorescence, flow citometry and immunogold we observed that the obtained polyclonal antibody against conserved intimin region recognizes the different intimin subtypes and suggests that it can be used as a tool for EPEC and EHEC detection. Besides, immuno-dot assay seems to be a possible alternative as a capture method.
【 授权许可】
CC BY-NC
All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202005130167217ZK.pdf | 374KB |
PDF