期刊论文详细信息
Brazilian Archives of Biology and Technology
Preparation and evaluation of modified composition for lyophilized kits of [Cu(MIBI)4]BF4 for [99mTc] technetium labeling
Marisa De Jesus De C. Lima1  Fabio Luiz Navarro Marques1  Miriam Roseli Yoshie Okamoto1  Alexandre Tales Garcez1  Marcelo Tatit Sapienza1  Carlos Alberto Buchpiguel1 
[1] ,Universidade de São Paulo Faculdade de Medicina Departamento de RadiologiaSão Paulo SP ,Brasil
关键词: [99mTc]technetium;    [[99mTc](MIBI)6]+;    radiopharmaceutical;    biodistribution;   
DOI  :  10.1590/S1516-89132005000700001
来源: SciELO
PDF
【 摘 要 】

The [Cu(MIBI)4]BF4 complex was synthesized and different formulations for lyophilized kits that could be cost-effectively used with different routines in nuclear medicine laboratories were investigated. In one preparation the kit components were kept similar to the Cardiolite® , except that the SnCl2.2H2O concentration was increased to 0.150 mg. In a second formulation, component concentrations were reduced to 1/5 of the original value and the SnCl2.2H2O concentration was adjusted to 0.04 mg. These products were labeled with maximum activities of 55.5 GBq and 8.14 GBq, respectively, and have shown an average radiochemical purity of 95 %. Biodistribution of the products was assessed by dissection in mice and in rabbits, and did not show any statistical difference when compared to Cardiolite®. In the synthesis of [Cu(MIBI)4]BF4 a new procedure was introduced for the synthesis of N-(2-methyl-propenyl)-formamide, with the use of microwave radiation as heat source. This modification reduced the reaction time to 25 seconds, while maintaining a yield of 68%.

【 授权许可】

CC BY-NC   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130165385ZK.pdf 91KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:3次