Revista Brasileira de Ciência Avícola | |
Evaluation of recycled tiles and OSB ceiling materials in closed broiler house prototypes | |
Jcm Cravo2  J Fiorelli1  Far Lahr1  R Da Fonseca2  Vc Da Cruz2  | |
[1] ,Universidade Estadual Paulista Júlio de Mesquita Filho | |
关键词: Broiler house environment; recycled tiles; thermal comfort; | |
DOI : 10.1590/S1516-635X2009000400002 | |
来源: SciELO | |
【 摘 要 】
This study aimed at evaluating the thermal performance of a modular ceiling system for poultry houses. The reduced- and distorted-scale prototypes used ceiling modules made of reforested wood and were covered with recycled long-life package tiles. The following parameters were measured for 21 days: tile internal surface temperature (ST), globe temperature and humidity index (WBGT), and radiant heat load (RHL). Measurements were made at times of highest heat load (11:00 am, 13:00 pm, and 03:00 pm). Collected data were analyzed by "R" statistics software. Means were compared by multiple comparison test (Tukey) and linear regression was performed, both at 5% significance level. The results showed that the prototype with the ceiling was more efficient to reduce internal tile surface temperature; however, this was not sufficient to provide a comfortable environment for broilers during the growout. Therefore, other techniques to provide proper cooling are required in addition to the ceiling.
【 授权许可】
CC BY
All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202005130162852ZK.pdf | 1151KB | download |