期刊论文详细信息
Sao Paulo Medical Journal
Comparison between cardiac output values measured by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury
Jorge Luís Dos Santos Valiatti2  José Luiz Gomes Do Amaral1 
[1] ,Faculdade de Medicina de CatanduvaCatanduva São Paulo
关键词: Cardiac output;    Carbon dioxide;    Thermodilution;    Adult respiratory distress syndrome;    Intensive care units;    Débito cardíaco;    Dióxido de carbono;    Termodiluição;    Síndrome do desconforto respiratório do adulto;    Unidade de terapia intensiva;   
DOI  :  10.1590/S1516-31802004000600002
来源: SciELO
PDF
【 摘 要 】

CONTEXT: Thermodilution, which is considered to be a standard technique for measuring the cardiac output in critically ill patients, is not free from relevant risks. There is a need to find alternative, noninvasive, automatic, simple and accurate methods for monitoring cardiac output at the bedside. OBJECTIVE: To compare cardiac output measurements by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury at two levels of severity (lung injury score, LIS: below 2.5, group A; and above 2.5, group B). TYPE OF STUDY: Comparative, prospective and controlled study. SETTING: Intensive Care Units of two university hospitals. METHODS: Cardiac output was measured by thermodilution and partial carbon dioxide rebreathing. Twenty patients with acute lung failure (PaO2/FiO2 < 300) who were under mechanical ventilation and from whom 294 measurements were taken: 164 measurements in group A (n = 11) and 130 in group B (n = 9), ranging from 14 to 15 determinations per patient. RESULTS: There was a poor positive correlation between the methods studied for the patients from groups A (r = 0.52, p < 0.001) and B (r = 0.47, p < 0.001). The application of the Bland-Altman test made it possible to expose the lack of agreement between the methods (group A: -0.9 ± 2.71 l/min; 95% CI = -1.14 to -0.48; and group B: -1.75 ± 2.05 l/min; 95% CI = -2.11 to -1.4). The comparison of the results (Student t and Mann-Whitney tests) within each group and between the groups showed significant difference (p = 0.000, p < 0.05). DISCUSSION: Errors in estimating CaCO2 (arterial CO2 content) from ETCO2 (end-tidal CO2) and situations of hyperdynamic circulation associated with dead space and/or increased shunt possibly explain our results. CONCLUSION: Under the conditions of this study, the results obtained allow us to conclude that, in patients with acute lung injury, the cardiac output determined by partial rebreathing of CO2 differs from the measurements obtained by thermodilution. This difference becomes greater, the more critical the lung injury is.

【 授权许可】

CC BY   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130155455ZK.pdf 382KB PDF download
  文献评价指标  
  下载次数:16次 浏览次数:19次