期刊论文详细信息
Sao Paulo Medical Journal
Mid-arm circumference and mid-arm/head circumference ratio in term newborns
Bettina Barbosa Duque Figueira1  Conceição Aparecida De Mattos Segre1 
[1] ,Instituto de Assistência Médica ao Servidor Público Estadual de São Paulo (IAMSP)São Paulo,Brazil
关键词: Cephalometry;    Anthropometry;    Fetal growth restriction;    Newborn;    Perímetro braquial;    Medição do perímetro braquial;    Cefalometria;    Antropometria;    Retardo do crescimento fetal;    Recém-nascido;   
DOI  :  10.1590/S1516-31802004000200004
来源: SciELO
PDF
【 摘 要 】

CONTEXT: Mid-arm circumference of the newborn is strongly associated with birth weight and is a very good indicator of low and insufficient birth weight. However, there are few Brazilian studies on the relationship between mid-arm and head circumferences and, thus, this does not form part of the routine evaluation for newborns. OBJECTIVES: To establish the mid-arm circumference and mid-arm/head circumference ratio in a population of term newborns. TYPE OF STUDY: Cross-sectional study carried out between June 1997 and August 1999. SETTING: Hospital Maternidade Leonor Mendes de Barros, São Paulo. PARTICIPANTS: Term newborns (66 males and 65 females) of appropriate growth for gestational age, whose mothers were healthy, were included in the study. MAIN MEASUREMENTS: Arm circumference, arm circumference/head circumference ratio, birth weight and gestational age were measured within 48 hours of birth. Data were considered significant when p < 0.01. RESULTS: The mean values for the mid-arm circumference were 10.76 cm (standard deviation, SD = 0.68) for females and 10.76 (SD = 0.81) for males. The mean value for the mid-arm/head circumference ratio was 0.31 (SD = 0.02) for both sexes. Mid-arm circumference values were significantly related to birth weight and gestational age, whereas mid-arm/head circumference ratio was related only to birth weight. CONCLUSIONS: Mid-arm circumference and mid-arm/head circumference ratio values were established for the studied population. It was possible to obtain curves for both mid-arm circumference and mid-arm/head circumference ratio in relation to birth weight. However, for mid-arm circumference, it was only possible to obtain curves in relation to gestational age. The use of the regression curves did not seem powerful enough to predict the mid-arm circumference and mid-arm/head circumference ratio in this population of term newborns. There were no gender differences for either of the measurements studied.

【 授权许可】

CC BY   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130155415ZK.pdf 299KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:19次