期刊论文详细信息
Brazilian Journal of Chemical Engineering
Flooding characteristics in pulsed packed extraction columns
M. Asadollahzadeh2  A. Haghighi-asl2  J. Safdari1  M. Torab-mostaedi1 
[1],Semnan University School of Chemical, Gas and Petroleum Engineering Semnan,Iran
关键词: Pulsed packed column;    Flooding;    Holdup;    Characteristic Velocity;    Throughput;   
DOI  :  10.1590/S0104-66322011000400009
来源: SciELO
PDF
【 摘 要 】
Flooding behavior of a 76.2 mm diameter pulsed packed column has been determined using four different liquid-liquid systems. The effects of pulsation intensity, flow ratio, interfacial tension, and packing geometry on flood point have been investigated. The results showed that the maximum throughput of the column decreases with an increase in pulsation intensity and flow ratio, while it increases with an increase in interfacial tension. The applicability of the characteristic velocity method to this type of column for the analysis of the flood point was examined and a marked deviation was observed between experimental results and values calculated by this method. Two new empirical correlations for flooding velocity and holdup at flooding are derived in terms of operating variables, packing characteristics, and physical properties of the liquid systems. Good agreement between prediction and experiments has been found for all operating conditions that were investigated.
【 授权许可】

CC BY   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130129030ZK.pdf 612KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:37次