| Brazilian Journal of Chemical Engineering | |
| Droplet size in a rectangular Venturi scrubber | |
| M. A. M. Costa1  P. R. Henrique1  J. A. S. Gonçalves1  J.r. Coury1  | |
| [1] ,Universidade Federal de São Carlos Departamento de Engenharia Química São Carlos SP ,Brasil | |
| 关键词: Venturi scrubber; droplet size; laser diffraction; | |
| DOI : 10.1590/S0104-66322004000200024 | |
| 来源: SciELO | |
PDF
|
|
【 摘 要 】
The Venturi scrubber is a device which uses liquid in the form of droplets to efficiently remove fine particulate matter from gaseous streams. Droplet size is of fundamental importance for the scrubber performance. In the present experimental study, a laser diffraction technique was used in order to measure droplet size in situ in a Venturi scrubber with a rectangular cross section. Droplet size distribution was measured as a function of gas velocity (58.3 to 74.9 m/s), liquid-to-gas ratio (0.07 to 0.27 l/m³), and distance from liquid injection point (64 to 173 mm). It was found that all these variables significantly affect droplet size. The results were compared with the predictions from correlations found in the literature.
【 授权许可】
CC BY
All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202005130128536ZK.pdf | 254KB |
PDF