期刊论文详细信息
Journal of the Brazilian Chemical Society
Optimization of the HS-SPME technique by using response surface methodology for evaluating chlorine disinfection by-products by GC in drinking water
Mauricio Aguirre-gonzález1  Gonzalo Taborda-ocampo2  Carmen Dussan-lubert2  Cristina Nerin2  Milton Rosero-moreano1 
[1] ,University of Caldas Chemistry Department Caldas,Colombia
关键词: gas chromatography-µECD;    surface response methodology;    solid phase microextraction;    trihalomethanes;    drinking water;   
DOI  :  10.1590/S0103-50532011001200013
来源: SciELO
PDF
【 摘 要 】

In this work the results of the optimization of headspace solid phase microextraction technique and determination by gas chromatography with micro electron capture detector (HS-SPME/GC-µECD) are described. The best condition of extraction for the four trihalomethanes in drinking water was reached through a response surface methodology's study using a composite 2(5) factorial design. Five experimental conditions of influence such as the type of fiber, extraction and desorption temperatures and extraction and desorption times were evaluated. The most influential factors in the technique of HS-SPME were the extraction temperature and extraction and desorption times. The type of fiber and the desorption temperature had little influence on extraction's efficiency. The best conditions were obtained with a fiber carboxen/polidimetilsiloxane (CAR/PDMS) of 75 µm, desorption temperature 250 ºC, extraction temperature 37.5 ºC, extraction time 30 min and a desorption time 4 min.

【 授权许可】

CC BY   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130106681ZK.pdf 500KB PDF download
  文献评价指标  