期刊论文详细信息
Journal of the Brazilian Chemical Society
A multicommuted flow system for dissolution studies of Captopril in pharmaceutical preparations
Mariana A Sanchez2  Diogo L Rocha2  Wanessa R Melchert2  Fábio R. P Rocha1 
[1] ,Universidade de São Paulo Instituto de Química São Paulo SP ,Brazil
关键词: flow analysis;    multicommutation;    dissolution profiles;    captopril;    spectrophotometry;   
DOI  :  10.1590/S0103-50532011000500002
来源: SciELO
PDF
【 摘 要 】

A flow-based analytical procedure exploiting multicommutation is proposed for captopril determination and the construction of dissolution curves. The procedure is based on the redox reaction between Cu(II) and the drug with the subsequent complexation of Cu(I) with 4,4'-dicarboxy-2,2'-bichinoline (BCA) and spectrophotometric detection. A linear response was observed between 25 and 300 µmol L-1 captopril and the detection limit was estimated as 7 µmol L-1 (99.7% confidence level). The coefficient of variation (n = 20) and sampling rate were 2.2% and 47 determinations per hour, respectively, consuming 290 µg of BCA and generating 3.6 mL of waste per determination. The results for seven pharmaceutical samples agreed with those obtained by the reference volumetric procedure at the 95% confidence level. The dissolution profiles attained with a lab-made dissolution apparatus agreed with those reported in the literature, with a coefficient of variation of 1.8% for three replicates of the reference product

【 授权许可】

CC BY   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130106484ZK.pdf 389KB PDF download
  文献评价指标  