| Acta Cirurgica Brasileira | |
| Simulation-based ultrasound-guided central venous cannulation training program | |
| Rafael Denadai1  Andreia Padilha Toledo1  Danielle Milani Bernades1  Felipe Daldegan Diniz1  Fernanda Brandão Eid1  Livia Maria Marcondes De Moura Lanfranchi1  Luciana Chamone Amaro1  Natalia Mariana Germani1  Vinicius Gutierrez Parise1  Claudio Nascimento Pacheco Filho1  Rogério Saad-hossne1  | |
| 关键词: Education; Models; Educational; Learning; Residency; Surgery; Teaching Materials; Ultrasonography; Ultrasonography; Interventional; Vascular Access Devices; | |
| DOI : 10.1590/S0102-86502014000200010 | |
| 来源: SciELO | |
PDF
|
|
【 摘 要 】
PURPOSE:To propose a simulation-based ultrasound-guided central venous cannulation skills' training program, during residency.METHODS:This study describes the strategies for learning the ultrasound-guided central venous cannulation on low-fidelity bench models. The preparation of bench models, educational goals, processes of skill acquisition, feedback and evaluation methods were also outlined. The training program was based on key references to the subject.RESULTS:It was formulated a simulation-based ultrasound-guided central venous cannulation teaching program on low-fidelity bench models.CONCLUSION:A simulation-based inexpensive, low-stress, no-risk learning program on low-fidelity bench models was proposed to facilitate acquisition of ultrasound-guided central venous cannulation skills by residents-in-training before exposure to the living patient.
【 授权许可】
CC BY
All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202005130100977ZK.pdf | 1464KB |
PDF