期刊论文详细信息
Química Nova
Determinação de ascarel em óleo isolante de transformadores
Izoldir Antonello1  Eduardo Humeres1  Ivan Gonçalves De Souza1  Nito Angelo Debacher1  Alexandre Rios Martins2 
[1] ,Universidade Federal de Santa Catarina Departamento de Química Florianópolis SC ,Brasil
关键词: ascarel;    PCBs;    dechlorination;   
DOI  :  10.1590/S0100-40422007000300034
来源: SciELO
PDF
【 摘 要 】

The contamination level of silicon oil used as insulation liquid in high-voltage transformers by ascarel (PCBs) is above those permitted by the Brazilian law. Thus new techniques able to detect ascarel, with low operational costs, are very attractive. The present work proposes an analysis of the contamination levels of silicon oil using the following techniques: naphthalene anion radical reaction for ascarel dechlorination; and potentiometry with an ion-selective electrode for chloride ion determination. The data obtained with the proposed methodology agree well with those from the official methodology, (method IEC 61619).

【 授权许可】

CC BY-NC   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130062068ZK.pdf 56KB PDF download
  文献评价指标  