期刊论文详细信息
Revista Brasileira de Oftalmologia
Efficacy of three different methods for side port incision wound sealing
Fabiana K. Kashiwabuchi2  Yasin A. Khan2  Murilo W. Rodrigues Jr2  Jiangxia Wang1  Peter J. Mcdonnell2  Yassine J. Daoud2 
[1] ,The Johns Hopkins University School of Medicine The Wilmer Eye Institute Baltimore Maryland ,USA
关键词: Endophthalmitis;    Cataract extraction;    Limbus corneae;    Intraocular pressure;    Biomechanics;    Endoftalmite;    Extração de catarata;    Limbo da córnea;    Pressão intraocular;    Biomecânica;   
DOI  :  10.1590/S0034-72802013000600005
来源: SciELO
PDF
【 摘 要 】

PURPOSE: To evaluate wound leakage and bacteria-sized particle influx in differently corneal sealed side port incisions. METHODS: Four 1.5mm tunnel squared incisions were created in each of four cadaveric human eyes. In each cornea, one incision was left unsealed, whereas the other three incisions were sealed using a 10-0 nylon suture, cyanoacrylate glue, or stromal hydration, respectively. A Seidel and an India ink test were performed on each eye. During each Seidel test, flourescein was applied, the IOP increased from 15 to 80mmHg, and the IOP at which each incision started to leak recorded. During each India ink test, ink was placed on the eye and rinsed out with balanced salt solution (BSS). Ink penetration was then measured by planimetry at physiologic conditions and after an IOP plunge from 80mmHg to 0mmHg. RESULTS: Regardless of IOP variations, no leakage or ink inflow was observed through the glued incisions. In contrast, leakage did occur in the other three sealing methods, albeit at significantly different IOP levels in each one (p=0.013). Ink inflow occurred in these sealing methods at physiologic IOP and, to a significantly greater extent, after the IOP challenge (p<0.05). At both of these IOP conditions, the differences in ink influx among these three incision-sealing methods were deemed statistically insignificant. CONCLUSION: This study showed that glue was more effective at preventing wound leakage and bacteria-sized particle influx than other commonly used methods especially hydrosealing.

【 授权许可】

CC BY   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130022840ZK.pdf 539KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:23次