期刊论文详细信息
Revista Brasileira de Oftalmologia
Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomy
Juan Carlos Sánchez Caballero2  Virgilio Centurion1 
[1] ,Instituto de Moléstias OcularesSão Paulo SP ,Brasil
关键词: Intraocular lens;    Anterior chamber;    keratotomy;    radial;    Biometry;    Axial length;    eye;    Lentes intraoculares;    Câmara anterior;    Ceratotomia radial;    Biometria;    Comprimento axial do olho;   
DOI  :  10.1590/S0034-72802013000200006
来源: SciELO
PDF
【 摘 要 】

OBJECTIVE: To analyze refractive results in postoperative cataract surgery in eyes previously submitted to keratotomy using Haigis formula and data provided by IOL Master®optical biometer. METHODS: The measurements for IOL calculation were obtained through optical biometry by partial coherence interferometry (IOL Master®- Zeiss, 5.4 and 5.5 version) that provides us with the axial length, the central keratometry of 2.5mm, white-to-white diameter and anterior chamber anatomical depth. The formula chosen was Haigis. The surgical technique applied was with the scleral incision at 1.5 mm from the limbus, with scleral-corneal tunnel of 2.2 mm wide, phacoemulsification using INFINITI Ozil®- Alcon and implantation of hydrophobic acrylic aspheric intraocular lens - SN60WF®- Alcon. RESULTS: We studied 20 eyes submitted to keratotomy in the past and currently with cataract with indication for cataract surgerywith intraocular lens implantation using phacoemulsification. Postoperative spherical equivalent was plano in 40% of the eyes and lower than -1.00 in 85% of the eyes. CONCLUSION: The optical biometry by partial coherence interferometry associated with Haigis formula is a valid alternative in IOL calculation for eyes submitted to keratotomy. The refractive results are highly predictable and reproducible.

【 授权许可】

CC BY   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130022782ZK.pdf 100KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:31次