Analysis of the time-velocity curve in phase-contrast magnetic resonance imaging: a phantom study
Jieun Park1  Junghun Kim1  Sinjae Hyun2  Sung Won Youn3  Eun-Ju Kang4  Ki-Nam Lee4  Vojtěch Suchánek5  Hui Joong Lee5  Yongmin Chang5  Jongmin Lee5 
[1] Department of Biomedical Engineering, Kyungpook National University, Daegu, Republic of Korea;Department of Biomedical Engineering, Mercer University, Macon, GA, US;Department of Radiology, Catholic University of Daegu Medical Center, Daegu, Republic of Korea;Department of Radiology, Dong-A University College of Medicine, Busan, Republic of Korea;Department of Radiology, Kyungpook National University & Hospital, Daegu, Republic of Korea;
关键词: Pulsatile flow;    time-velocity curve;    flow analysis;    phase-contrast magnetic resonance imaging;    doppler ultrasonography;   
DOI  :  10.1080/24699322.2019.1649066
来源: publisher
PDF
【 摘 要 】

The aim of this study was to analyze the characteristics of time-velocity curve acquired by phase-contrast magnetic resonance imaging (PC-MRI) using an in-vitro flow model as a reference for hemodynamic studies. The time- velocity curves of the PC-MRI were compared with Doppler ultrasonography (US) and also compared with those obtained in the electromagnetic flowmeter. The correlation between techniques was analyzed using an electromagnetic flowmeter as a reference standard; the maximum, minimum, and average velocities, full-width at half-maximum (FWHM), and ascending gradient (AG) were measured from time-velocity curves. The correlations between an electromagnetic flowmeter and the respective measurement technique for the PC-MRI and Doppler US were found to be high (mean R2 > 0.9, p < 0.05). These results indicate that these measurement techniques are useful for measuring blood flow information and reflect actual flow. The PC-MRI was the best fit for the minimum velocity and FWHM, and the maximum velocity and AG were the best fit for Doppler US. The PC-MRI showed lower maximum velocity value and higher minimum velocity value than Doppler US. Therefore, PC-MRI demonstrates more obtuse time-velocity curve than Doppler US. In addition, the time- velocity curve of PC-MRI could be calibrated by introducing formulae that can convert each measurement value to a reference standard value within a 10% error. The PC-MRI can be used to estimate the Doppler US using this formula.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202004237208648ZK.pdf 1822KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:10次