期刊论文详细信息
Journal of Cardiothoracic Surgery
Aortic root surgery with the CARDIOROOT vascular graft: results of a prospective multicenter post-market surveillance study
Jaroslav Lindner1  Amando Gamba2  Giordano Tasca2  Laurent Barandon3  Petr Santavy4  Jan Burkert5  Carlo Antona6 
[1] 0000 0000 9100 9940, grid.411798.2, Chirurgická klinika kardiovaskulární chirurgie, General University Hospital, Prague, Czech Republic;0000 0004 0493 6789, grid.413175.5, Operative Unit of Cardiac Surgery, Cardiovascular Department, ASST-Lecco, Ospedale “A. Manzoni”, Via Dell’Eremo 9/11, 23900, Lecco, Italy;0000 0004 0593 7118, grid.42399.35, Department of Cardiac and Vascular Surgery, Centre Hospitalier Universitaire (CHU) de Bordeaux, Bordeaux, France;0000 0004 0609 2225, grid.412730.3, Kardiochirurgická klinika, University Hospital Olomouc, Olomouc, Czech Republic;0000 0004 0611 0905, grid.412826.b, Dept. Cardiac Surgery, Klinika kardiovaskulární chirurgie, University Hospital Motol, Motol, Czech Republic;0000 0004 1757 2822, grid.4708.b, Università degli Studi di Milano, Division of Cardio-Vascular Surgery, Department of Cardio-Cerebro-Vascular, ASST Fatebenefratelli-Sacco, Milan, Italy;
关键词: Aortic root surgery;    Vascular graft;    Sinus of Valsalva;    CARDIOROOT;   
DOI  :  10.1186/s13019-019-0914-y
来源: publisher
PDF
【 摘 要 】

BackgroundSparing Aortic Valve procedure requires to reproduction of the geometry of the physiologic anatomy of the aortic root. Thus, the materials adopted may make a difference. CARDIOROOT is a one-piece collagen-coated woven vascular graft with pseudo-sinuses, which was designed for use in the treatment of aortic root disease. We report the results of a prospective, multicenter, observational post-market surveillance study evaluating the safety and performance of the CARDIOROOT in patients requiring aortic root surgery.MethodsPatients with aortic root disease suitable for treatment with a vascular graft with pseudo-sinuses CARDIOROOT graft were eligible for participation. The enrolled patients were assessed intraoperatively, post-operatively, at discharge and at 1-year. Sites assessed complications at each visit, and recorded any reported adverse events. The study endpoint was mortality and complications through 1-year post-procedure.ResultsFifty-two patients were enrolled from 6 European centers. All procedures were technically successful. Operative mortality was 1.9%: one patient suffered hemorrhagic shock unrelated to the graft 1 day following surgery. At 1-year follow-up the survival rate was 96.2%, with a late death due to pneumonia 5 months post-procedure. Eleven serious adverse events occurred in 7 patients, which included cardiac complications (pericardial effusion, myocardial infarction and ventricular arrhythmia), infection (pericardial infection, deep sternal infection and superficial sternal infection), vascular disorders, including hemorrhagic shock and pleural effusion requiring drainage. Nine of the 11 events were deemed procedure-related by the local investigator, and all were deemed unrelated to the device. There were no reports of graft-related adverse events, infection, occlusion or graft failure.ConclusionsThe results of this 1-year follow-up study showed that the CARDIOROOT vascular graft is safe and effective for the treatment of aneurysmal aortic root in immediate and mid-term follow-up. However, longer term follow-up is needed before conclusions can be made on the long-term safety and effectiveness.Trial registrationClinicalTrials.gov Identifier: NCT01609270. Registered 31 May 2012.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202004233456133ZK.pdf 1874KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:3次