期刊论文详细信息
Sensors
Determination of Vitamin C (Ascorbic Acid) Using High Performance Liquid Chromatography Coupled with Electrochemical Detection
Zbynek Gazdik3  Ondrej Zitka1  Jitka Petrlova1  Vojtech Adam1  Josef Zehnalek1  Ales Horna2  Vojtech Reznicek3  Miroslava Beklova4 
[1] Department of Chemistry and Biochemistry, Faculty of Agronomy, Zemedelska 1, CZ-613 00 Brno, Mendel University of Agriculture and Forestry, Czech Republic;Tomas Bata University, T.G. Masaryka 275, CZ-762 72 Zlin, Czech Republic;Department of Breeding and Propagation of Horticultural Plants, Faculty of Horticulture, Valticka 337, CZ-691 44 Lednice, Faculty of Agronomy, Zemedelska 1, CZ-613 00 Brno, Mendel University of Agriculture and Forestry, Czech Republic;Department of Veterinary Ecology and Environmental Protection, Faculty of Veterinary Hygiene and Ecology, University of Veterinary and Pharmaceutical Sciences, Palackeho 1-3, CZ-612 42 Brno, Czech Republic
关键词: Ascorbic Acid;    Flow Injection Analysis;    High Performance Liquid Chromatography;    Electrochemical Detection;    Fruits;    Pharmaceutical Preparation;    Human Blood Serum;   
DOI  :  10.3390/s8117097
来源: mdpi
PDF
【 摘 要 】

Vitamin C (ascorbic acid, ascorbate, AA) is a water soluble organic compound that participates in many biological processes. The main aim of this paper was to utilize two electrochemical detectors (amperometric – Coulouchem III and coulometric – CoulArray) coupled with flow injection analysis for the detection of ascorbic acid. Primarily, we optimized the experimental conditions. The optimized conditions were as follows: detector potential 100 mV, temperature 25 °C, mobile phase 0.09% TFA:ACN, 3:97 (v/v) and flow rate 0.13 mL·min-1. The tangents of the calibration curves were 0.3788 for the coulometric method and 0.0136 for the amperometric one. The tangent of the calibration curve measured by the coulometric detector was almost 30 times higher than the tangent measured by the amperometric detector. Consequently, we coupled a CoulArray electrochemical detector with high performance liquid chromatography and estimated the detection limit for AA as 90 nM (450 fmol per 5 μL injection). The method was used for the determination of vitamin C in a pharmaceutical preparations (98 ± 2 mg per tablet), in oranges (Citrus aurantium) (varied from 30 to 56 mg/100 g fresh weight), in apples (Malus sp.) (varied from 11 to 19 mg/100 g fresh weight), and in human blood serum (varied from 38 to 78 μM). The recoveries were also determined.

【 授权许可】

CC BY   
© 2008 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190058131ZK.pdf 517KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:28次