[1] Medical College of Nankai University, Tianjin 300071, P.R. China; E-Mail:;College of Life Science, Nankai University, Tianjin 300071, P.R. China; E-Mails:;College of Medicine and Life Sciences, University of Jinan, Jinan 250022, P.R. China; E-Mails:;College of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P.R. China; E- Mails:College of Medicine and Life Sciences, University of Jinan, Jinan 250022, P.R. China;;Xiyuan Hospital, China Academy of Traditional Chinese Medicine, Beijing 100091, P.R. China; E- Mails:
关键词: Resonant mirror biosensor;    IAsys;    Quartz crystal microbalance;    Endothelin-1 (ET-1);    Paeoniae Radix 801;    Interaction;   
DOI  :  10.3390/s8128275
来源: mdpi
PDF
【 摘 要 】

A resonant mirror biosensor, IAsys, and a quartz crystal microbalance (QCM) are known independently as surface sensitive analytical devices capable of label-free and in situ bioassays. In this study, an IAsys and a QCM are employed for a new study on the action mechanism of Paeoniae Radix 801 (P. radix 801) by detecting the specific interaction between P. radix 801 and endothelin-1 (ET-1). In the experiments, ET-1 was immobilized on the surfaces of the IAsys cuvette and the QCM substrate by surface modification techniques, and then P. radix 801 solution was contacted to the cuvette and the substrate, separately. Then, the binding and interaction process between P. radix 801 and ET-1 was monitored by IAsys and QCM, respectively. The experimental results showed that P. radix 801 binds ET-1 specifically. The IAsys and QCM response curves to the ET-1 immobilization and P. radix 801 binding are similar in reaction process, but different in binding profiles, reflecting different resonation principles. Although both IAsys and QCM could detect the interaction of P. radix 801 and ET-1 with high reproducibility and reliability through optimization of the ET-1 coating, the reproducibility and reliability obtained by IAsys are better than those obtained by QCM, since the QCM frequency is more sensitive to temperature fluctuations, atmospheric changes and mechanical disturbances. However, IAsys and QCM are generally potent and reliable tools to study the interaction of P. radix 801 and ET-1, and can conclusively be applied to the action mechanism of P. radix 801.

【 授权许可】

CC BY   
© 2008 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190057668ZK.pdf 243KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:12次