Sensors | |
An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines | |
Remus Pusca1  Raphael Romary1  Andrian Ceban1  | |
[1] Univ Lille Nord de France, F-59000 Lille, France; E-Mails: | |
关键词: AC motors; fault diagnosis; magnetic field sensors; maintenance; | |
DOI : 10.3390/s101110448 | |
来源: mdpi | |
【 摘 要 】
This paper presents an original non-invasive procedure for the diagnosis of electromagnetic devices, as well as AC electrical rotating machines using two external flux coil sensors that measure the external magnetic field in the machines’ vicinity. The diagnosis exploits the signal delivered by the two sensors placed in particular positions. Contrary to classical methods using only one sensor, the presented method does not require any knowledge of a presumed machine’s healthy former state. On the other hand, the loading operating is not a disturbing factor but it is used to the fault discrimination. In order to present this procedure, an internal stator inter-turn short-circuit fault is considered as well.
【 授权许可】
CC BY
© 2010 by the authors; licensee MDPI, Basel, Switzerland.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202003190051494ZK.pdf | 401KB | download |