期刊论文详细信息
Sensors
Signal Injection as a Fault Detection Technique
Jordi Cusidó1  Luis Romeral2  Juan Antonio Ortega2  Antoni Garcia2 
[1] MCIA Research Group, Universitat Politècnica de Catalunya, C. Colom 1, Terrassa, 08222 Catalunya, Spain;
关键词: fault detection;    induction motor;    electrical drives;   
DOI  :  10.3390/s110303356
来源: mdpi
PDF
【 摘 要 】

Double frequency tests are used for evaluating stator windings and analyzing the temperature. Likewise, signal injection on induction machines is used on sensorless motor control fields to find out the rotor position. Motor Current Signature Analysis (MCSA), which focuses on the spectral analysis of stator current, is the most widely used method for identifying faults in induction motors. Motor faults such as broken rotor bars, bearing damage and eccentricity of the rotor axis can be detected. However, the method presents some problems at low speed and low torque, mainly due to the proximity between the frequencies to be detected and the small amplitude of the resulting harmonics. This paper proposes the injection of an additional voltage into the machine being tested at a frequency different from the fundamental one, and then studying the resulting harmonics around the new frequencies appearing due to the composition between injected and main frequencies.

【 授权许可】

CC BY   
© 2011 by the authors; licensee MDPI, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190050011ZK.pdf 2187KB PDF download
  文献评价指标  