Sergio Odín Flores-Valle1  Omar Ríos-Bernÿ1  Jorge Chanona-Pérez1  Tomas Fregoso-Aguilar1  José A. Morales-González1  Oscar Jesús Prado-Rubianes1  Rafael Herrera-Bucio1  Pablo López-Albarán1  Ángel Morales-González1  Vicente Garibay-Febles1  Enrique Godínez Domínguez1  Christian Kennes1  Ma. Carmen Veiga-Barbazán1 
[1] 1Laboratorio de Catálisis y Materiales, ESIQIE-Instituto Politécnico Nacional, Zacatenco, 07738 Mexico, D.F., Mexico
关键词: downward flow;    biofilter;    backwashing;    air sparging;    biofilm;    clogging;    batch assay;    filter bed;    biomass control;   
DOI  :  10.3390/molecules16086927
来源: mdpi
PDF
【 摘 要 】

After 6 months of operation a long-term biofilter was stopped for two weeks and then it was started up again for a second experimental period of almost 1.3 years, with high toluene loads and submitted to several physical and chemical treatments in order to remove excess biomass that could affect the reactor’s performance due to clogging, whose main effect is a high pressure drop. Elimination capacity and removal efficiency were determined after each treatment. The methods applied were: filling with water and draining, backwashing, and air sparging. Different flows and temperatures (20, 30, 45 and 60 °C) were applied, either with distilled water or with different chemicals in aqueous solutions. Treatments with chemicals caused a decrease of the biofilter performance, requiring periods of 1 to 2 weeks to recover previous values. The results indicate that air sparging with pure distilled water as well as with solutions of NaOH (0.01% w/v) and NaOCl (0.01% w/v) were the treatments that removed more biomass, working either at 20, 30 or 45 °C and at relatively low flow rates (below 320 L h−1), but with a high biodegradation inhibition after the treatments. Dry biomass (g VS) content was determined at three different heights of the biofilter in order to carry out each experiment under the same conditions. The same amount of dry biomass when applying a treatment was established so it could be considered that the biofilm conditions were identical. Wet biomass was used as a control of the biofilter’s water content during treatments. Several batch assays were performed to support and quantify the observed inhibitory effects of the different chemicals and temperatures applied.

【 授权许可】

CC BY   
This is an open access article distributed under the Creative Commons Attribution License (CC BY) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

【 预 览 】
附件列表
Files Size Format View
RO202003190048617ZK.pdf 686KB PDF download
  文献评价指标  
  下载次数:12次 浏览次数:34次