期刊论文详细信息
Sensors
Real-Time Telemetry System for Amperometric and Potentiometric Electrochemical Sensors
Wei-Song Wang5  Hong-Yi Huang1  Shu-Chun Chen5  Kuo-Chuan Ho3  Chia-Yu Lin3  Tse-Chuan Chou4  Chih-Hsien Hu6  Wen-Fong Wang2  Cheng-Feng Wu2 
[1] Graduate Institute of Electrical Engineering, National Taipei University, Taipei 10617, Taiwan; E-Mail:;Department of Computer Science and Information Engineering, National Yunlin University of Science & Technology, Yunlin 64002, Taiwan; E-Mails:;Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan; E-Mails:;Department of Chemical Engineering, Tatung University, Taipei 104, Taiwan; E-Mail:;Department of Electrical Engineering, National Cheng Kung University, Tainan 70101, Taiwan; E-Mails:;Department of Chemical Engineering, National Cheng Kung University, Tainan 70101, Taiwan; E-Mail:
关键词: electrochemical sensor;    telemetry system;    potentiostat;    instrumentation amplifier;   
DOI  :  10.3390/s110908593
来源: mdpi
PDF
【 摘 要 】

A real-time telemetry system, which consists of readout circuits, an analog-to-digital converter (ADC), a microcontroller unit (MCU), a graphical user interface (GUI), and a radio frequency (RF) transceiver, is proposed for amperometric and potentiometric electrochemical sensors. By integrating the proposed system with the electrochemical sensors, analyte detection can be conveniently performed. The data is displayed in real-time on a GUI and optionally uploaded to a database via the Internet, allowing it to be accessed remotely. An MCU was implemented using a field programmable gate array (FPGA) to filter noise, transmit data, and provide control over peripheral devices to reduce power consumption, which in sleep mode is 70 mW lower than in operating mode. The readout circuits, which were implemented in the TSMC 0.18-μm CMOS process, include a potentiostat and an instrumentation amplifier (IA). The measurement results show that the proposed potentiostat has a detectable current range of 1 nA to 100 μA, and linearity with an R2 value of 0.99998 in each measured current range. The proposed IA has a common-mode rejection ratio (CMRR) greater than 90 dB. The proposed system was integrated with a potentiometric pH sensor and an amperometric nitrite sensor for in vitro experiments. The proposed system has high linearity (an R2 value greater than 0.99 was obtained in each experiment), a small size of 5.6 cm × 8.7 cm, high portability, and high integration.

【 授权许可】

CC BY   
© 2011 by the authors; licensee MDPI, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190048063ZK.pdf 1788KB PDF download
  文献评价指标  
  下载次数:16次 浏览次数:19次