Challenges | |
The Exergetic, Environmental and Economic Effect of the Hydrostatic Design Static Pressure Level on the Pipe Dimensions of Low-Energy District Heating Networks | |
Hakan ጋrahim Tol1  | |
关键词: low-energy; low-temperature; district heating; substation; pressure loss; maximum static pressure; optimization; environmental impact; | |
DOI : 10.3390/challe4010001 | |
来源: mdpi | |
【 摘 要 】
Low-Energy District Heating (DH) systems, providing great energy savings by means of very low operating temperatures of 55 °C and 25 °C for supply and return respectively, were considered to be the 4th generation of the DH systems for a low-energy future. Low-temperature operation is considered to be used in a low-energy DH network to carry the heat produced by renewable and/or low grade energy sources to low-energy Danish buildings. In this study, a comparison of various design considerations with different levels of maximum design static pressures was performed, and their results evaluated in terms of energetic, exergetic, economic, and environmental perspectives.
【 授权许可】
CC BY
© 2013 by the authors; licensee MDPI, Basel, Switzerland.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202003190039074ZK.pdf | 474KB | download |