期刊论文详细信息
Sensors
A New Method for Flow Rate Measurement in Millimeter-Scale Pipes
Haifeng Ji1  Xuemin Gao2  Baoliang Wang2  Zhiyao Huang1 
[1] State Key Laboratory of Industrial Control Technology, Department of Control Science and Engineering, Zhejiang University, Hangzhou 310027, China;
关键词: flow rate measurement;    Capacitively Coupled Contactless Conductivity Detection;    cross correlation flow measurement;    millimeter-scale pipes;   
DOI  :  10.3390/s130201563
来源: mdpi
PDF
【 摘 要 】

Combining the Capacitively Coupled Contactless Conductivity Detection (C4D) technique and the principle of cross correlation flow measurement, a new method for flow rate measurement in millimeter-scale pipes was proposed. The research work included two parts. First, a new five-electrode C4D sensor was developed. Second, with two conductivity signals obtained by the developed sensor, the flow rate measurement was implemented by using the principle of cross correlation flow measurement. The experimental results showed that the proposed flow rate measurement method was effective, the developed five-electrode C4D sensor was successful, and the measurement accuracy was satisfactory. In five millimeter-scale pipes with different inner diameters of 0.5, 0.8, 1.8, 3.0 and 3.9 mm respectively, the maximum relative difference of the flow rate measurement between the reference flow rate and the measured flow rate was less than 5%.

【 授权许可】

CC BY   
© 2013 by the authors; licensee MDPI, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190038694ZK.pdf 409KB PDF download
  文献评价指标  