| Sensors | |
| Temperature Measurement in WTE Boilers Using Suction Pyrometers | |
| Fabio Rinaldi1  | |
| 关键词: temperature measurement; waste-to-energy plants; uncertainty; suction pyrometers; | |
| DOI : 10.3390/s131115633 | |
| 来源: mdpi | |
PDF
|
|
【 摘 要 】
The temperature of the flue-gas in the post combustion zone of a waste to energy (WTE) plant has to be maintained within a fairly narrow range of values, the minimum of which is prescribed by the European Waste Directive 2000/76/CE, whereas the maximum value must be such as to ensure the preservation of the materials and the energy efficiency of the plant. A high degree of accuracy in measuring and controlling the aforementioned temperature is therefore required. In almost the totality of WTE plants this measurement process is carried out by using practical industrial thermometers, such as bare thermocouples and infrared radiation (IR) pyrometers, even if affected by different physical contributions which can make the gas temperature measurements incorrect. The objective of this paper is to analyze errors and uncertainties that can arise when using a bare thermocouple or an IR pyrometer in a WTE plant and to provide a method for the
【 授权许可】
CC BY
© 2013 by the authors; licensee MDPI, Basel, Switzerland.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202003190031698ZK.pdf | 1075KB |
PDF