Materials | |
Influence of Column Axial Load and Heat Affected Zone on the Strength of Aluminium Column Web in Tension | |
Gianfranco De Matteis1  Gianluca Sarracco1  Giuseppe Brando1  | |
[1] Department of Engineering and Geology, University “G. d’Annunzio” of Chieti-Pescara, Pescara 65127, |
|
关键词: connections; joints; aluminium; column web in tension; axial load; heat affected zone; | |
DOI : 10.3390/ma7053557 | |
来源: mdpi | |
【 摘 要 】
The component method for aluminium joints has been recently introduced in some codes and guidelines. Nevertheless, it is still in need of some development and improvement, as in some cases it was obtained by adapting the existing formulations that are valid for steel. The current paper presents the main outcomes of a parametric analysis carried out by means of finite element (FE) numerical models for determining the influence of both column axial load and heat affected zone—in the case of welded details—on the structural response of the column web in a tension component. The proposed study integrates previous research carried out by the authors, where the influence of the assumed alloy was investigated and interpreted by corrective parameters expressed as a function of both the material strain hardening and ductility.
【 授权许可】
CC BY
© 2014 by the authors; licensee MDPI, Basel, Switzerland
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202003190026390ZK.pdf | 386KB | download |