期刊论文详细信息
Energies
Performance of a 250 kW Organic Rankine Cycle System for Off-Design Heat Source Conditions
Ben-Ran Fu1  Sung-Wei Hsu2  Yuh-Ren Lee2  Jui-Ching Hsieh2  Chia-Ming Chang2 
[1] Green Energy and Environment Research Laboratories, Industrial Technology Research Institute, Hsinchu 31040, Taiwan;
关键词: organic Rankine cycle;    off-design conditions;    thermal efficiency;   
DOI  :  10.3390/en7063684
来源: mdpi
PDF
【 摘 要 】

An organic Rankine cycle system comprised of a preheater, evaporator, condenser, turbine, generator, and pump was used to study its off-design performance and the operational control strategy. R245fa was used as the working fluid. Under the design conditions, the net power output is 243 kW and the system thermal efficiency is 9.5%. For an off-design heat source flow rate (mW), the operating pressure was controlled to meet the condition that the R245fa reached the liquid and vapor saturation states at the outlet of the preheater and the evaporator, respectively. The analytical results demonstrated that the operating pressure increased with increasing mW; a higher mW yielded better heat transfer performance of the preheater and required a smaller evaporator heat capacity, and the net power output and system thermal efficiency increased with increasing mW. For the range of mW studied here, the net power output increased by 64.0% while the total heat transfer rate increased by only 9.2%. In summary, off-design operation of the system was examined for a heat source flow rate which varied by –39.0% to +78.0% from the designed rate, resulting in –29.2% to +16.0% and –25.3% to +12.6% variations in the net power output and system thermal efficiency, respectively.

【 授权许可】

CC BY   
© 2014 by the authors; licensee MDPI, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190025121ZK.pdf 426KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:17次