Sensors | |
Implementation of Ultrasonic Sensing for High Resolution Measurement of Binary Gas Mixture Fractions | |
Richard Bates6  Michele Battistin11  Stephane Berry11  Alexander Bitadze6  Pierre Bonneau11  Nicolas Bousson8  George Boyd9  Gennaro Bozza11  Olivier Crespo-Lopez11  Enrico Da Riva11  Cyril Degeorge4  Cecile Deterre1  Beniamino DiGirolamo11  Martin Doubek5  Gilles Favre11  Jan Godlewski11  Gregory Hallewell8  Ahmed Hasib9  Sergey Katunin2  Nicolas Langevin8  Didier Lombard11  Michel Mathieu8  Stephen McMahon3  Koichi Nagai6,10  Benjamin Pearson9  David Robinson6,12  Cecilia Rossi6,7  Alexandre Rozanov8  Michael Strauss9  Michal Vitek5  Vaclav Vacek5  | |
[1] Deutsches Elektronen-Synchrotron, Notkestraβe 85, D-22607 Hamburg, Germany; E-Mail:;B.P. Konstantinov Petersburg Nuclear Physics Institute (PNPI), Orlova Roscha, RU-188300, Russia; E-Mail:;STFC Rutherford Appelton Laboratory—Harwell Oxford, Didcot, OX11 OQX, UK; E-Mail:;Department of Physics, Indiana University, Bloomington, IN 47405 7015, USA; E-Mail:;Czech Technical University, Technická 4, 16607, Praha Czech Republic; E-Mails:;SUPA School of Physics and Astronomy, University of Glasgow, G627QB, UK; E-Mails:;Academy of Sciences of the Czech Republic, 11000 Praha, Czech Republic; E-Mail:;Centre de Physique des Particules de Marseille, 163 Avenue de Luminy, 13288 Marseille, France; E-Mails:;Department of Physics & Astronomy, University of Oklahoma, Norman, OK 73019, USA; E-Mails:;Department of Physics, Oxford University, Oxford OX1 3RH, UK; E-Mail:;CERN, 1211 Geneva 23, Switzerland; E-Mails:;Department of Physics and Astronomy, University of Cambridge, Cambridge, CB3 0HE, UK; E-Mail: | |
关键词: ultrasonic; binary gas analysis; leak detection; | |
DOI : 10.3390/s140611260 | |
来源: mdpi | |
【 摘 要 】
We describe an ultrasonic instrument for continuous real-time analysis of the fractional mixture of a binary gas system. The instrument is particularly well suited to measurement of leaks of a high molecular weight gas into a system that is nominally composed of a single gas. Sensitivity < 5 × 10−5 is demonstrated to leaks of octaflouropropane (C3F8) coolant into nitrogen during a long duration (18 month) continuous study. The sensitivity of the described measurement system is shown to depend on the difference in molecular masses of the two gases in the mixture. The impact of temperature and pressure variances on the accuracy of the measurement is analysed. Practical considerations for the implementation and deployment of long term,
【 授权许可】
CC BY
© 2014 by the authors; licensee MDPI, Basel, Switzerland.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202003190024738ZK.pdf | 1457KB | download |