期刊论文详细信息
Sensors
Hyperspectral Sensing for Turbid Water Quality Monitoring in Freshwater Rivers: Empirical Relationship between Reflectance and Turbidity and Total Solids
Jiunn-Lin Wu1  Chung-Ru Ho3  Chia-Ching Huang2  Arun Lal Srivastav2  Jing-Hua Tzeng2 
[1] Department of Computer Science and Engineering, National Chung Hsing University, 250 Kuo Kuang Rd., Taichung 402, Taiwan; E-Mail:;Department of Soil and Environment Sciences, National Chung Hsing University, 250 Kuo Kuang Rd., Taichung 402, Taiwan; E-Mails:;Department of Marine Environmental Informatics, National Taiwan Ocean University, 2 Pei-Ning Rd., Keelung 202, Taiwan; E-Mail:
关键词: hyperspectral sensing;    multiple-regression;    neural network;    remote sensing;    total solids;    turbidity;    turbid water;   
DOI  :  10.3390/s141222670
来源: mdpi
PDF
【 摘 要 】

Total suspended solid (TSS) is an important water quality parameter. This study was conducted to test the feasibility of the band combination of hyperspectral sensing for inland turbid water monitoring in Taiwan. The field spectral reflectance in the Wu river basin of Taiwan was measured with a spectroradiometer; the water samples were collected from the different sites of the Wu river basin and some water quality parameters were analyzed on the sites (in situ) as well as brought to the laboratory for further analysis. To obtain the data set for this study, 160 in situ sample observations were carried out during campaigns from August to December, 2005. The water quality results were correlated with the reflectivity to determine the spectral characteristics and their relationship with turbidity and TSS. Furthermore, multiple-regression (MR) and artificial neural network (ANN) were used to model the transformation function between TSS concentration and turbidity levels of stream water, and the radiance measured by the spectroradiometer. The value of the turbidity and TSS correlation coefficient was 0.766, which implies that turbidity is significantly related to TSS in the Wu river basin. The results indicated that TSS and turbidity are positively correlated in a significant way across the entire spectrum, when TSS concentration and turbidity levels were under 800 mg·L−1 and 600 NTU, respectively. Optimal wavelengths for the measurements of TSS and turbidity are found in the 700 and 900 nm range, respectively. Based on the results, better accuracy was obtained only when the ranges of turbidity and TSS concentration were less than 800 mg·L−1 and less than 600 NTU, respectively and used rather than using whole dataset (R2 = 0.93 versus 0.88 for turbidity and R2 = 0.83 versus 0.58 for TSS). On the other hand, the ANN approach can improve the TSS retrieval using MR. The accuracy of TSS estimation applying ANN (R2 = 0.66) was better than with the MR approach (R2 = 0.58), as expected due to the nonlinear nature of the transformation model.

【 授权许可】

CC BY   
© 2014 by the authors; licensee MDPI, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190019009ZK.pdf 1055KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:7次